NMR spectrometer that incorporates ultra-high accuracy RF circuitry utilizing the latest digital high frequency technology
Description
- NMR spectrometer that incorporates ultra-high accuracy RF circuitry utilizing the latest digital high frequency technology.
- Identification and Quantification for specific nucleus.
- Advanced one-dimensional techniques like 1D_NOE, pure shift NMR etc.
- STD NMR to interpret the interaction between protein and ligand.
- VT NMR from -100℃ to +150℃.
- No-D NMR, Protonated solvents can be used to record the spectrum
- To Analyse and Characterise organic molecules plant extract, Active Pharmaceutical Intermediates and Drug formulations.
- Observed nuclei : 1H,19F, 31P to 15N, 39K, 109Ag
Specification
| Make | JEOL India Pvt Ltd |
|---|---|
| Model | JNM-ECZL400s |
NMR Charges
| S. No | Solvent | Experiment PRICEs based on solvent selection |
Internal JSS AHER institutions (GST NA) |
Academic (Including GST) |
Government and R&D Lab (including GST) |
Industry (including GST) |
|---|---|---|---|---|---|---|
| 1 | CDCl3 | 1H NMR | 300 | 352 | 1416 | 2360 |
| 13C NMR | 400 | 472 | 1416 | 2360 | ||
| DEPT-135 | 500 | 590 | 1770 | 2360 | ||
| DEPT-90 | 500 | 590 | 1770 | 2360 | ||
| 19F NMR | 400 | 472 | 1416 | 2360 | ||
| 31P NMR | 400 | 472 | 1416 | 2360 | ||
| 2 | CD3OD | 1H NMR | 500 | 590 | 1652 | 2360 |
| 13C NMR | 600 | 708 | 1652 | 2360 | ||
| DEPT-135 | 700 | 826 | 1770 | 2360 | ||
| DEPT-90 | 700 | 826 | 1770 | 2360 | ||
| 19F NMR | 500 | 590 | 1652 | 2360 | ||
| 31P NMR | 500 | 590 | 1652 | 2360 | ||
| 3 | DMSO-d6 | 1H NMR | 400 | 472 | 1652 | 2360 |
| 13C NMR | 400 | 472 | 1652 | 2360 | ||
| DEPT-135 | 500 | 590 | 1770 | 2360 | ||
| DEPT-90 | 500 | 590 | 1770 | 2360 | ||
| 19F NMR | 400 | 472 | 1652 | 2360 | ||
| 31P NMR | 400 | 472 | 1652 | 2360 | ||
| 4 | D2O | 1H NMR | 400 | 472 | 1652 | 2360 |
| 13C NMR | 400 | 472 | 1652 | 2360 | ||
| DEPT-135 | 500 | 590 | 1770 | 2360 | ||
| DEPT-90 | 500 | 590 | 1770 | 2360 | ||
| 19F NMR | 400 | 472 | 1652 | 2360 | ||
| 31P NMR | 400 | 472 | 1652 | 2360 | ||
| 5 | Other | <text> |
NOTE
- 2D NMR experiments and other advanced experiments are charged based on number of hours required to record the experiment. There will be additional charges for additional scans based on requirements.
- For NMR data with J value in journal format will be charged extra Rs. 100/-
- Quotation will be generated based on the User Requirement
- The raw data will be stored in the system for only three months. Please ensure that you collect your data soon after the analysis is completed
Frequently asked questions
You can book instrument time by filling out the request form available at USIC Booking Form. Ensure all required details are filled accurately for faster processing.
The facility is open to Internal (JSS AHER) faculty and students, as well as external academic institutions, government and R&D labs, and industries.
Payments must be made to the following account:
Account Name: JSS AHER Research Development Fund
A/c No: 64060381103
IFSC: SBIN0040547
Branch: S S Nagar, Mysuru
Solvent charges are additional and vary by solvent type. For example, CDCl₃ and D₂O are charged at ₹100 per sample, while DMSO-d₆ is ₹200 per sample. However, internal samples and noD NMR are exempt from solvent charges.
You may contact the USIC Team at JSS College of Pharmacy, Mysuru:
Phone: +91 9726447802
Email: usic@jssuni.edu.in